WELDING MONITOR-WM-EX

Spec:

feature

1.5.7-inch VGA color LCD touch screen
The current monitor WM-EX is equipped with a 5.7-inch VGA color LCD touch screen, which provides an intuitive operation interface so that users can easily view and control various settings.

2. Various monitoring
– The current monitor WM-EX can set 2-point upper limit and 2-point lower limit to ensure safety during operation.
– Two measurement intervals can be set for one measurement, and their current data can be measured separately to facilitate accurate monitoring of changes in different parameters.

3.Maximum
The welding time can be measured up to 9.99 seconds. The current monitor WM-EX can provide real-time welding time data to help users optimize the welding process.

4. Can measure 5 points of displacement
– The current monitor WM-EX can measure 5-point displacement, including work inspection, product dimensions and 3-point displacement to ensure that the product meets specifications.
– In addition, WM-EX supports ISO-17657 compatibility mode to facilitate users to conduct standardized testing and inspection.
 

Content:

Item / Function  Specification 
Display  5.7-inch, color LCD, VGA resolution (640 x 480 dots) 
Operating controls  Pressure-sensitive (resistive film) touch panel 
Languages  Display language: select Japanese, English, or simplified Chinese 
Print language: select Japanese or English 
Front and rear labels written in English 
Display screens  10 measurement values simultaneous display, 6 waveform simultaneous display  
All Cycle (current, voltage, displacement list per half cycle) 
Run Chart (2 waveforms + 10 measured values) 
Measurement condition 
settings 
127 conditions (channels)    Measurement current can be set for each channel 
Trigger conditions  Current, displacement, force, external analog input 
Measurement item  (Welding) current, voltage (between tips), displacement, force, external sensor (external analog 
input) 
Measurable current 
waveforms 
Welding current of following electric resistance welding machines 
Single-phase AC welding machine, single-phase rectified resistance welding machine, DC inverter 
resistance welding machine, AC inverter resistance welding machine, capacitor-type resistance 
welding machine (including AC seam welding machine) 
Current calculation 
method 
Normal mode:    Average RMS value (1/2 cycle or 1 ms average RMS current value) 
ISO mode:    RMS value of welding time (conforms to ISO-17657) 
Measurement accuracy 
(with respect to full 
scale) 
Current: ±1.5%  RMS max. 
Voltage: DC ±1.0%  max. ±2.0%  RMS max. 
Force: ±3.0%  max. 
Power: ±1.5% max. 
External analog input: ±1.0% max. 
Displacement: ±15 μm max. at 1 μm max. sensor resolution ±150 μm max. at 1.1 μm or above 
Maximum measurement 
time 
AC **Hz mode: equivalent to 10 s (50 Hz: 0 to 499.5 cycles, 60 Hz: 0 to 599.0 cycles) 
SEAM **Hz mode: equivalent to 5000 cycles (0 to 4999.5 cycles) 
DC ms-SHORT mode: equivalent to 2 s (0 to 1990 ms) 
DC ms-LONG mode: equivalent to 10 s (0 to 9990 ms) 
DC **Hz-SHORT mode: equivalent to 2 s (50 Hz: 0 to 99.5 cycles, 60 Hz: 0 to 119.0 cycles) 
DC **Hz-LONG mode: equivalent to 10 s (50 Hz: 0 to 499.5 cycles, 60 Hz: 0 to 599.0 cycles) 
AC ms mode: equivalent to 10 s (0 to 9990 ms) 
Storage capacity  Final measured waveform: 1 waveform, measurement items: 2000 spots x 10 items 
Printer output  Thermal